(a) Check the resistance of the horn relay.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
A8 - T6
|
When battery voltage is not applied
|
10 kΩ or higher
|
|
A8 - T6
|
When battery voltage is applied to terminal A7 and T6
|
Below 1 Ω
|
If the result is not as specified, replace the integration relay.
|